mo.button does not work, what can I do?

If the mo.button does not work properly, check the following things:

  • mo.button is isolated installed. The ignition (EMC) can have an influence on the mo.button, therefore it should be installed in the handlebar.
  • Ignition suppressed? 5 kOhm, better still 10 kOhm spark plug connector used?
  • Green cable on mo.unit blue / basic connected to KILL input or on mo.unit V.2 connected to CONFIG input?
  • Check ground connection, the black cable of the mo.button must be connected to ground! It is best to use GND of the mo.unit.
  • Check if there is voltage at the mo.button! There is not supposed to be any voltage.
Did this answer your question? Thanks for the feedback There was a problem submitting your feedback. Please try again later.