motocsope tiny, speedster, vintage- pointer does not move / incomplete
The instrument must be installed correctly and the connecting cable of the instrument must not be exposed to any tensile or compressive stress.
The needle is moved by a servomotor, this servomotor can be affected by a load on the connecting cable in such a way that it cannot move freely.
When switching on the motoscope, the pointer should make a full deflection to 200 and return to 0.
If this is not the case please check the following:
- Battery voltage must not drop too much when switching on the motoscope
- Cable must be laid without tension and pressure
- Check wiring & connections
The device should also be tested when removed and also on another voltage source with 12V.
If the problem persists, please contact our motogadget support team.